Revision shaft DN 400/160/1500 with continuous backflow preventer is used - it is mounted on the sewer pipe usually for the case when it is possible to insert a "mole" into the sewer pipe for cleaning the branch when it gets clogged. If the sewer pipe is longer, we recommend inserting revision shafts every 20-25m. The sewer revision shaft with backflow preventer prevents the backflow of wastewater, sewer into the building or the passage of rodents into the dwellings. Use of the shaft with backflow preventer: The sewer revision shaft with backflow preventer is designed for use in sanitary waste systems or for rainwater. The recommended place for installing the shaft with backflow preventer is the sewer pipe between the building and the main waste network. The sewer shaft with backflow preventer serves as a revision shaft protecting buildings from flooding. Advantages of using the shaft with backflow preventer: Standard installation of the backflow preventer requires the use of a shaft made of plastic, concrete or other solid material with a diameter in the range of 800 to 1200 mm, and its installation often requires the use of heavy machinery. The sewer shaft with backflow preventer can be easily installed by one person without any heavy machinery. A very simple and effective mechanism, from which the component can be removed without the need to get inside the device, allows the use of shafts with a much smaller diameter DN 315 and DN 400. The revision shaft with backflow preventer does not require a specialist for maintenance. The highest quality stainless steel and polypropylene used in the production makes the shaft with backflow preventer resistant to corrosion, frost and chemical agents. The sewer shaft with backflow preventer is installed without the use of heavy machinery and is resistant to expansion. The maximum allowed depth for placing the revision shaft with backflow preventer is 5m. The maximum temperature of the medium flowing through the shaft is 95°C. Revision shaft DN 400/160/1500 with continuous backflow preventer includes: - shaft base 400/160 continuous with backflow preventer - shaft cover 400 - smooth shaft pipe 400 Watch the video: https://www.youtube.com/watch?v=ARqwDGf5MhgCác thông số bổ sung
| Danh mục hàng: | Tarkastuskaivot takaiskuventtiilillä 400 liitäntä DN 160 |
|---|---|
| EAN: | 8585054507924 |
| Saatavuus: | Varastossa tai toimittajalla |
| EAN: | 8585054507924 |
Đánh giá sản phẩm
Hãy là người đầu tiên đăng bài báo về mặt hàng này!
Thảo luận
Danh sách các thảo luận
M
Martin
I would like to kindly enquire whether this inspection shaft with a non-return valve is suitable for installation between a family house and the main sewer network, and whether one person is genuinely able to install it without the use of heavy machinery, given that standard non-return valve installations typically require shafts of 800 to 1200 mm in diameter.
A
ATRIA.SK
Yes, that is exactly the intended use — between the building and the main sewer line, to prevent backflow of wastewater into the house. Because this shaft has a DN 400 diameter instead of the usual 800–1200 mm, one person can handle the installation without any heavy equipment. The mechanism is also designed so that you can remove and service the flap without having to climb inside the shaft.